FEATURES:
- The 7-inch LCD touch screen and the intuitive menu simplified the operation.
- Portable, easy to carry and transport.
- Applied to all common lithium battery packs testing with various voltage levels.
- Equalizing maintenance test can activate the lithium battery performance completely.
- Support intelligent equalizing function, and equalizing maintenance parameter customization.
- Adopt wave width modulation technology, high efficiency, high power factor, low noise, low electromagnetic interference.
- Support multiple protection design and alarm settings of voltage, current, temperature abnormal to protect the battery and the balancer.
- Support the safety protection functions such as overvoltage, undervoltage, overcurrent, output short circuit, anti-reverse protection and overheating protection.
- Multiple discharge auto-stop conditions make testing mode more intelligent and flexible, and avoid over-charge and over-discharge.
- Customized setting the total charging time, constant voltage time, charging capacity, and charging current.
SPECIFICATIONS:
Power Input | AC 90~265V |
Data Communication | CAN RS485 |
Data Dump | U disk |
Data Storage | 16G |
Module Data Acquisition Communication | Harness sampling |
Group Voltage Accuracy | ≤±0.5%FS±0.3V, resolution: 0.001V |
Cell Voltage Accuracy | ≤±0.1%FS±5mV, resolution: 0.001V |
Current Measurement Accuracy | ≤±1%FS+0.2A, resolution: 0.1A |
Charging/Discharging Voltage Range | DC 2~260V |
Charging Current Range | 0~100A, maximum power 4.4kw |
Discharging Current Range | 0~100A, maximum power 7.2kw |
Charging Control |
Constant current charging + constant voltage charging |
Discharging Mode | Constant current discharging |
Charging and Discharging Data Acquisition |
In-camera active measurement + external can communication data acquisition |
Electric Box Charging and Discharging Protection | Battery string overcharge and over discharge,
battery string temperature is too high protection |
Main Unit Protection | Over temperature, over current, current runaway trigger shutdown protection |
Shutdown Actuator | DC air circuit breaker + release |
Reverse Connection Protection | Power failure of power line and main cable |
Over-temperature Protection | 100℃ resistance box over temperature 85℃; radiator over temperature 100℃ |
Alarm Prompt | LCD prompt + buzzer |
SAFETY TEST | |
Breaking Down Test | AC input-metal shell: 2200Vdc 1 min AC input-metal shell |
DC input-output: 2200Vdc 1 min DC input-case | |
WORKING ENVIRONMENT | |
Radiation Method | Forced air cooling |
Temperature | Working temperature range: -5~40℃
Storage temperature: -20~70℃ |
Humidity | Relative humidity 0~90%(40±2℃) |
Elevation | Rated altitude 2000m |
SIZE AND WEIGHT | |
Dimensions/Weight | 445*329*540(mm)/25.6kg |